Line 2: Line 2:
  
 ^ Release Version    ^ Section                  ^ Description                    ^ ^ Release Version    ^ Section                  ^ Description                    ^
-| 2.1 | Dashboard  |Need a way to create virtual buttons (On/Off, Manual/Auto)                      | +| 2.1 | Dashboard ADDED - Ability to create toggle buttons on the dashboard (On/Off, Manual/Auto, etc.)                      | 
-| 2.1 | Dashboard   | Long labels do not contain themselves to the component bounds and automatically resize.  Example, LED box, a long label will go on top the box and overwrite other components.       +| 2.1 | Dashboard   FIXED - Long labels would extend beyond the bounds of the dashboard component       | 
-|2.1| Dashboard  | Long labels do not contain themselves to the component bounds and automatically resize.  Example, LED box, a long label will go on top the box and overwrite other components.   | +|2.1  | HMI  | ADDED - Automatic refresh between connected clients. Saving a change on one client forces the other client to update automatically.  |
-|2.1 | Comms | ADDED - Ability to write to DE-4000 Modbus Registers. Custom handlers can be created to received written data and store or take other action.  +
-|2.1  | HMI  | ADDED - Automatic refresh between connected clients. Saving a change on one client forces the other client to updat.  |+
 |2.1  | Dashboard  | FIXED - Could not add a dashboard page between other pages   | |2.1  | Dashboard  | FIXED - Could not add a dashboard page between other pages   |
-|2.1  | Dashbaord  |FIXED - Clicking on the delete (trashcan) would sometimes bring up the channel selector and add a component instead of removing the selected component.   | +|2.1  | Dashboard  |FIXED - Clicking on the delete (trashcan) would sometimes bring up the channel selector and add a component instead of removing the selected component.   | 
-|2.1  | Dashbaord  |ADDED - Ability to set background color of Virtual Channels to show alarm state, faults,etc   |+|2.1  | Dashboard  |ADDED - Ability to set background color of Virtual Channels to show alarm state, faults,etc   |
 |2.1  | Config  |ADDED - Fault output can be inverted, activate when faulted or activate when not faulted  | |2.1  | Config  |ADDED - Fault output can be inverted, activate when faulted or activate when not faulted  |
 |2.1  | Config  | ADDED - Start up sequence, can turn on and turn off multiple DS outputs in a single start up state  | |2.1  | Config  | ADDED - Start up sequence, can turn on and turn off multiple DS outputs in a single start up state  |
-|2.1  | Dashboard |When defining an output there is now a single button channel selector  |+|2.1  | Dashboard |CHANGED - Output channel selector now uses a single button component  |
 |2.1  | Dashboard  | ADDED - Up to 10 dashboard pages can now be configured. The previous limit was 7 pages.  | |2.1  | Dashboard  | ADDED - Up to 10 dashboard pages can now be configured. The previous limit was 7 pages.  |
 +|2.1  | Dashboard  | ADDED - Custom graphical dashboard pages can be created for custom applications including vertical markets |
 |2.1  | Setup  | FIXED - Debug page numerous bug fixes. All outputs are now forced off when entering and exiting the debug page.  | |2.1  | Setup  | FIXED - Debug page numerous bug fixes. All outputs are now forced off when entering and exiting the debug page.  |
 |2.1  |Setup  | FIXED - System would not power up if a terminal board was missing. Now the system will power up and alert the user of the missing terminal board(s).  | |2.1  |Setup  | FIXED - System would not power up if a terminal board was missing. Now the system will power up and alert the user of the missing terminal board(s).  |
-|2.1  | Comms  | ADDED - Ability to read and write 32 bit integer and Floating point values over modbus (combine two 16-bit registers)  |+|2.1  | Comms  | ADDED - Ability to read and write 32 bit integer and floating point values over modbus (combines two 16-bit registers)  |
 |2.1  | Config  |FIXED -  Several issues with loading and saving parameters have been resolved  | |2.1  | Config  |FIXED -  Several issues with loading and saving parameters have been resolved  |
 |2.1  | Config  | FIXED - Fixed error where "SAVE FAILED" would sometimes appear when saving configuration  | |2.1  | Config  | FIXED - Fixed error where "SAVE FAILED" would sometimes appear when saving configuration  |
-|2.1  | Comms  |Modbus, system can be remotely locked with a modbus writecan only be unlocked with a code by someone with the unlock code   +|2.1  | Comms  |ADDED - System can be remotely locked with a modbus write. Panel can later be unlocked remotely or an unlock code can be provided. 
-|2.1  | Comms  |All the main button presses (stop, reset, cancel timers etc.) can be initiated with modbus writes +|2.1  | Comms  |ADDED - All the main button presses (stop, reset, start, cancel timers) can be initiated with modbus writes 
-|2.1  | Comms  |Can define cutsom modbus write registers. Can assign code to run when a modbus register is written to. Functions can use this then as a passed variable +|2.1  | Comms  |ADDED - Can define custom modbus write registers. Can assign code to run when a modbus register is written to. Custom functions can then use this received register value  as a variable 
-|2.1  | Application  |High overspeed fault resolved   | +|2.1  | Application  |FIXED - Erroneous high overspeed fault resolved   | 
-|2.1  |Config  |Ability to configure 10 PIDs using global PID page  | +|2.1  |Config  |ADDED - Ability to configure 10 PIDs using global PID page (previous limit was 2 PIDs)  | 
-|2.1  |Config  |Parameters page, user can define custom parameters that can be used in script.  | +|2.1  |Config  |ADDED - Parameters page. When new functions are createdthe programmer can define custom parameters, grouped by category, with default values. The end user can configure the new function by modifying the default parameters, if needed.  | 
-|2.1  |Dashboard  |New display elements for the dashborad pageToggle button, Up/down, up/down input  | +|2.1  |Dashboard  |ADDED - New display elements for the dashboard pageToggle button, Up/down, up/down input  | 
-|2.1  |HMI  |HMI responsiveness has been improved +|2.1  |HMI  |FIXED - HMI responsiveness has been improved 
-|2.1  |HMI  |Visible feedback on button presses of the HMI  | +|2.1  |HMI  |ADDED - Visible feedback on button presses of the HMI  | 
-|2.1  |Dashboard  |Can change background color on dashboard LED elements +|2.1  |Dashboard  |ADDED - Can change background color on dashboard LED elements 
-|2.1  |Setup  |Cal bug fixed  | +|2.1  |Setup  |FIXED - Channel calibration bug fixed  | 
-|2.1  |Dashboard  |Custom fault function field  | +|2.1  |Dashboard  |ADDED - Custom faults can be triggered from a script function 
-|2.1  |Comms  |Extended custom fault function can define extended fault codes that can be accessed over modbus +|2.1  |Comms  |ADDED - Extended custom fault function can define extended fault codes that can be accessed over modbus 
-|2.1  |Ext Device  |Can take value on an external device in a script and use it in the application +|2.1  |Ext Device  |ADDED - Ability to read register from an externally connected Modbus device and use this register value in a custom application 
-|2.1  |Comms  |Can add 10000 and 00000 registers to the dashboard   +|2.1  |Comms  |ADDED - Modbus Coils and Inputs (register blocks 00000 and 10000) can now be added as dashboard elements  
-|2.1  |Config  |api req() is now added  +|2.1  |Config  |ADDED - New api_req() function can be used for extended system access
-|2.1  |Class C timer has default of 30 seconds. If trying to change a warning message will pop up  | +|2.1  |Config |ADDED - To ensure safe configuration by default, class C timer has default of 30 seconds. If this time value is changed to 0, a warning message will appear, informing the user that in this configuration, the channel will never arm if the setpoint is never reached  |
- +
- +
- +
- +
- +
- +
- +
- +
- +
- +
- +
- +
- +
- +
- +
- +
- +
- +