^ Release Version ^ Section ^ Description ^ | ^ Release Version ^ Section ^ Description ^ |
| 2.1 | Channels |Low set points should be before high set points (Safety and Control) | | | 2.1 | Dashboard | ADDED - Ability to create toggle buttons on the dashboard (On/Off, Manual/Auto, etc.) | |
| 2.1 | Dashboard |Need a way to create virtual buttons (On/Off, Manual/Auto) | | | 2.1 | Dashboard | FIXED - Long labels would extend beyond the bounds of the dashboard component | |
| 2.1 | Dashboard | Long labels do not contain themselves to the component bounds and automatically resize. Example, LED box, a long label will go on top the box and overwrite other components. | | |2.1 | HMI | ADDED - Automatic refresh between connected clients. Saving a change on one client forces the other client to update automatically. | |
|2.1| Dashboard | Long labels do not contain themselves to the component bounds and automatically resize. Example, LED box, a long label will go on top the box and overwrite other components. | | |2.1 | Dashboard | FIXED - Could not add a dashboard page between other pages | |
|2.1 | Comms | Modbus registers are all read only, where are all the settings for setpoints and such? WE NEED THIS AS A STANDARD for all control panels. Everything should be configurable via modbus. | | |2.1 | Dashboard |FIXED - Clicking on the delete (trashcan) would sometimes bring up the channel selector and add a component instead of removing the selected component. | |
|2.1 | HMI | Must have a refresh button on the Dashboard and values page so it will reload the channel labels. Currently you must reboot each time to force a reload. | | |2.1 | Dashboard |ADDED - Ability to set background color of Virtual Channels to show alarm state, faults,etc | |
|2.1 | Dashboard | Need to be able to Insert a new HMI page between two existing pages. | | |2.1 | Config |ADDED - Fault output can be inverted, activate when faulted or activate when not faulted | |
|2.1 | Dashbaord |Sometimes clicking on the delete (trashcan) brings up the channel selector and adds a component instead of just removing the component. | | |2.1 | Config | ADDED - Start up sequence, can turn on and turn off multiple DS outputs in a single start up state | |
|2.1 | Dashbaord |Need ability to set background color of Virtual Channels to show alarm state, faults,etc | | |2.1 | Dashboard |CHANGED - Output channel selector now uses a single button component | |
| |2.1 | Dashboard | ADDED - Up to 10 dashboard pages can now be configured. The previous limit was 7 pages. | |
| |2.1 | Dashboard | ADDED - Custom graphical dashboard pages can be created for custom applications including vertical markets | |
| |2.1 | Setup | FIXED - Debug page numerous bug fixes. All outputs are now forced off when entering and exiting the debug page. | |
| |2.1 |Setup | FIXED - System would not power up if a terminal board was missing. Now the system will power up and alert the user of the missing terminal board(s). | |
| |2.1 | Comms | ADDED - Ability to read and write 32 bit integer and floating point values over modbus (combines two 16-bit registers) | |
| |2.1 | Config |FIXED - Several issues with loading and saving parameters have been resolved | |
| |2.1 | Config | FIXED - Fixed error where "SAVE FAILED" would sometimes appear when saving configuration | |
| |2.1 | Comms |ADDED - System can be remotely locked with a modbus write. Panel can later be unlocked remotely or an unlock code can be provided. | |
| |2.1 | Comms |ADDED - All the main button presses (stop, reset, start, cancel timers) can be initiated with modbus writes | |
| |2.1 | Comms |ADDED - Can define custom modbus write registers. Can assign code to run when a modbus register is written to. Custom functions can then use this received register value as a variable | |
| |2.1 | Application |FIXED - Erroneous high overspeed fault resolved | |
| |2.1 |Config |ADDED - Ability to configure 10 PIDs using global PID page (previous limit was 2 PIDs) | |
| |2.1 |Config |ADDED - Parameters page. When new functions are created, the programmer can define custom parameters, grouped by category, with default values. The end user can configure the new function by modifying the default parameters, if needed. | |
| |2.1 |Dashboard |ADDED - New display elements for the dashboard page. Toggle button, Up/down, up/down input | |
| |2.1 |HMI |FIXED - HMI responsiveness has been improved | |
| |2.1 |HMI |ADDED - Visible feedback on button presses of the HMI | |
| |2.1 |Dashboard |ADDED - Can change background color on dashboard LED elements | |
| |2.1 |Setup |FIXED - Channel calibration bug fixed | |
| |2.1 |Dashboard |ADDED - Custom faults can be triggered from a script function | |
| |2.1 |Comms |ADDED - Extended custom fault function can define extended fault codes that can be accessed over modbus | |
| |2.1 |Ext Device |ADDED - Ability to read a register from an externally connected Modbus device and use this register value in a custom application | |
| |2.1 |Comms |ADDED - Modbus Coils and Inputs (register blocks 00000 and 10000) can now be added as dashboard elements | |
| |2.1 |Config |ADDED - New api_req() function can be used for extended system access| |
| |2.1 |Config |ADDED - To ensure safe configuration by default, class C timer has default of 30 seconds. If this time value is changed to 0, a warning message will appear, informing the user that in this configuration, the channel will never arm if the setpoint is never reached | |
| |